D 244 432 00 | Power supply terminals for E-bus
The D 244 432 00 power supply terminals are used to refresh the E-bus. Data is exchanged between the coupler and the EtherCAT Terminal over the E-bus. Each terminal draws a certain amount of current from the E-bus (see “current consumption E-bus” in the technical data).
This current is fed into the E-bus by the relevant coupler’s power supply unit. In configurations with a large number of terminals it is possible to use the D 244 432 00 in order to supply an extra 2 A to the E-bus. The D 244 432 00 has a diagnostic function which is displayed by LED and on the process image.
Technical data | D 244 432 00 |
Technology |
power supply terminal |
Short-circuit-proof |
yes |
Input voltage |
24 V DC |
Input current |
approx. 70 mA + (E-bus/4) |
Output voltage |
5 V for E-bus supply |
Max. output current |
2 A |
Current consumption E-bus |
– |
Electrical isolation |
– |
Power contacts |
24 V DC max./10 A max. |
Diagnostics in the process image |
yes |
Special features |
standard EL supply |
Weight |
approx. 65 g |
Operating/storage temperature |
0…+55 °C/-25…+85 °C |
Relative humidity |
95 %, no condensation |
Vibration/shock resistance |
conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission |
conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. class/installation pos. |
IP 20/variable |
Pluggable wiring |
for all ESxxxx terminals |
Approvals |
CE, UL, Ex |
You can also find more documentation on the following site